Dan Dugan wrote:

>
>Typical correspondences:
>
>dBV/Pa   Open Circuit mV
>-60         1.0
>-50         3.2 (hot dynamic mic)
>-40        10.0 (condensor mic)
>    0      1000.0 (1 Volt)

...

>
>The 804's output is -49,...you'd have 4 dB more preamp noise with the Heil=
.


Rob D. wrote:
>  I recall the noise creeping down pretty low in the spectrum with
>the RE-16 (1.4mV/Pa) and RE-20 (1.5 mV/Pa).

So the noise I was hearing with the dynamic mics was that of the
Nagra 4.2's mic pre,.. Do you recall what this noise spec is with the
quieter pre option? On par with the better pres we are working with
today? Rob D.






<Prev in Thread] Current Thread [Next in Thread>
Admin

The University of NSW School of Computer and Engineering takes no responsibility for the contents of this archive. It is purely a compilation of material sent by many people to the naturerecordists mailing list. It has not been checked for accuracy nor its content verified in any way. If you wish to get material removed from the archive or have other queries about the archive e-mail Andrew Taylor at this address: andrewt@cse.unsw.EDU.AU