--- In "weide72" <> wrote:
>
> Hi-
>
> Just wondering what the correct connection would be to connect a DB-9
> Male connector to the COM2 port on the TS-7260? Jim Jackson's link on
> this group's links page differs from the TS-7260 manual. All I need
> to connect is TX, RX, and GND. Thanks.
>
> Ryan
>
The serial ports on the TS-7260 conform to the same pinout as the
serial port on an IBM compatible computer. It is a DTE configuration:
pin 2 = RX
pin 3 = TX
pin 5 = GND
The same cable you used when operating your peripheral device from a
PC can be used with the TS-7260 COM2 port.
Additionally, to use COM2 for general use instead of for a login
session, you must make sure that the login process is not running for
that tty device. It is running by default. You must edit the
/etc/inittab file to comment out the line where getty is run against
/dev/ttyAM1 then reboot. It is located in the last few lines of that
file.
Furthermore, your source code needs some adjustment. See prior
messages for details.
Amardeep