--- In  "weide72" <> wrote:
>
> Hi-
> 
> Just wondering what the correct connection would be to connect a DB-9 
> Male connector to the COM2 port on the TS-7260?  Jim Jackson's link on 
> this group's links page differs from the TS-7260 manual.  All I need 
> to connect is TX, RX, and GND. Thanks.
> 
> Ryan
>

The serial ports on the TS-7260 conform to the same pinout as the
serial port on an IBM compatible computer.  It is a DTE configuration:

pin 2 = RX
pin 3 = TX
pin 5 = GND

The same cable you used when operating your peripheral device from a
PC can be used with the TS-7260 COM2 port.

Additionally, to use COM2 for general use instead of for a login
session, you must make sure that the login process is not running for
that tty device.  It is running by default.  You must edit the
/etc/inittab file to comment out the line where getty is run against
/dev/ttyAM1 then reboot.  It is located in the last few lines of that
file.

Furthermore, your source code needs some adjustment.  See prior
messages for details.

Amardeep







 
Yahoo! Groups Links

<*> To visit your group on the web, go to:
    http://groups.yahoo.com/group/ts-7000/

<*> To unsubscribe from this group, send an email to:
    

<*> Your use of Yahoo! Groups is subject to:
    http://docs.yahoo.com/info/terms/
 



<Prev in Thread] Current Thread [Next in Thread>
Admin

Disclaimer: Neither Andrew Taylor nor the University of NSW School of Computer and Engineering take any responsibility for the contents of this archive. It is purely a compilation of material sent by many people to the birding-aus mailing list. It has not been checked for accuracy nor its content verified in any way. If you wish to get material removed from the archive or have other queries about the archive e-mail Andrew Taylor at this address: andrewt@cse.unsw.EDU.AU