dawydiuk wrote:
>
> > p.s. if anyone from Technologics is reading this - why don't you
> get the
> > schematic, and user guide corrected then people wouldn't get
> confused?
>
> The information in the manual is correct, if you read just below the
> pinout for the Com2 header you will notice a large arrow with the
> following comment
>
> "Note: The COM2 serial port header uses a non-standard numbering
> scheme. This was done so the header pins would have the same numbering
> as the corresponding DB-9 pin; i.e. pin 3 (TXD) on the header connects
> to pin 3 on the DB-9."
>
> The COM ports use this style numbering:
>
> 6 7 8 9 10
> 1 2 3 4 5
>
> I'll ensure this numbering scheme is added to the manual to avoid
> confusion.
>
> //Eddie
>
Ok, I've got a ribbon cable - 10 pin Berg on one end, DB-9 on the
other. And
it's a 1:1 cable - 1-1, 2-2, 3-3.... (no 10) Doesn't work. Now maybe
I'm missing a module?
Or something else? But that's what started this thread, I tired Com2
with that cable
didn't work, grabbed the serial2usb from my main PC and tried that - to
no avail.
Here's my bottom line, I need to RS232 out of my box - Com2 - first
choice, USB -
second choice - haven't been able to get either to work. Help! Pls.
Also - my PC - has a program statserial - has anyone ported to a 7200?
Yahoo! Groups Links
<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/ts-7000/
<*> To unsubscribe from this group, send an email to:
<*> Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/
|