Either
- you're not using the /etc/inittab entries exactly as given, so please check
again, especially make sure that the "lgn1" entry is commented out.
See http://www.linuxcertif.com/man/8/getty/304568/ for the getty
man page.
- you've multiple getty's running. Try rebooting.
Jon
On Wed, Jun 27, 2012 at 11:25:50AM -0700, Damian Miralles wrote:
> Hello:
> I did the changes on the /etc/inittab/
> #
> # Start console logins on both COM Ports
> #
> lgn0:12345:respawn:/sbin/getty -L 115200 ttyAM0
> # Disable COM2 logins, but set baud rate
> com2:12345:once:/sbin/getty -L -n -t 1 1200 ttyAM1
> #lgn1:12345:respawn:/sbin/getty -L 115200 ttyAM1
>
> I manage to set the port to the 1200 baud rate as desired and I am able of
> sending and receiving data to the desired speed, however I do notice that i
> keep having an input on the com2 port as login, let's say that if i have
> connected COM2 to my pc serial port and com1 as the console, i still get the
> message
> "ts7200 login" on the serial port window connected to COM2. in adittion I can
> login since the COM2 PORT without any problem
> When editing the /etc/inittab/ I believe that the dual login console will be
> disbale, any idea why i am getting this result
> Thanks
> Damian
------------------------------------
Yahoo! Groups Links
<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/ts-7000/
<*> Your email settings:
Individual Email | Traditional
<*> To change settings online go to:
http://groups.yahoo.com/group/ts-7000/join
(Yahoo! ID required)
<*> To change settings via email:
<*> To unsubscribe from this group, send an email to:
<*> Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/
|