On 3/2/10, sanjuan34 <> wrote:
> Hi. I'm trying to get CAN bus working using a TS-CAN1 on a 7530 board. I'm
> loading the kernel module with out any errors using the following parameters
>
> insmod -f lincan.ko io=0x150 hw=tscan irq=33
>
> (for IRQ6, JP4 on, I/O address 150, JP1 and JP2 off)
>
> I can run lincan utilities like sendburst, sendcan, readcan with out error;
> however, I'm getting no activity on CAN_H and CAN_L. All I see when looking
> at either line is a very odd looking 60Hz signal, about 2Vp-p. The signal is
> persistent whether the kernel module is loaded or not.
What other CAN nodes do you have connected?
Joel Morgan
Morgan Millwright Services, Inc.
------------------------------------