Re: MS Confusion

Subject: Re: MS Confusion
From: "Tim Nielsen" supernielsen
Date: Sat Jun 2, 2007 9:45 am ((PDT))
It shouldn't be that way. MS 'should' be completely in phase and
fully mono compatible. A couple of things to consider:

Are you positive you fed the center mic into the 'left' channel of
the MS plugin, and the figure-8 to the 'right' side? I'm not sure
doing it the other way would cause the phase issues you're seeing,
but they do have to be set correctly.

Are you sure your mic capsules were coincedent? For MS to work
properly, the capsules need to be aligned in the vertical plane.

These are two possibilities.


On Jun 2, 2007, at 9:34 AM, Phil Tyler wrote:

> > I can't seem to wrap my head around MS and have uncovered a
> confusing
> > issue. I have discovered that after decoding my MS recordings (MDA
> > plug-in,Voxengo MSED, or Audition) they are 100% out of phase
> according
> > to Audition's Phase Analyzer. When I invert one channel, they return
> > into phase. Where in my chain would I inadvertently be inverting the
> > phasing? Or does decoded MS always have an inverted phasing?








<Prev in Thread] Current Thread [Next in Thread>
Admin

The University of NSW School of Computer and Engineering takes no responsibility for the contents of this archive. It is purely a compilation of material sent by many people to the naturerecordists mailing list. It has not been checked for accuracy nor its content verified in any way. If you wish to get material removed from the archive or have other queries about the archive e-mail Andrew Taylor at this address: andrewt@cse.unsw.EDU.AU