Hi,
I am testing the COM3 of my TS-7260 board (without OP-2TTLCOM option) for
hardware flow control (use of RTS and CTS signals). My testing is done as below:
1. Connect COM1 and COM3 on my TS-7260 board via a null modem cable.
2. Open two telnet sessions to my TS-7260 board.
3. Start picocom on COM1 on one telnet session, with baudrate 38400 and
hardware flow control.
$ ./picocom -b 38400 -f h /dev/ttyAM0
4. Start picocom on COM3 on the other telnet session, with baudrate 38400 and
hardware flow control.
$ ./picocom -b 38400 -f h /dev/ttyTS0
Surprisingly, both COM1 and COM3 couldn't send and receive data between them.
If I start both picocoms with NO flow control, both COM1 and COM3 can send and
receive data between them without any problem.
So, I wonder if anybody has experience in using hardware flow control on COM3
of TS-7260. Your advice is much appreciated.
Thanks
Kok Hua
------------------------------------