Hi,
Thanks all for replying to my question. Sorry I was tied up the past
several days and didn't got a chance to try.
Today I turned off the flow control in the hyperterminal and entered
redboot. So this must be the problem.
Thanks again,
- Don
On Mon, Apr 14, 2008 at 8:05 AM, wimpunk <> wrote:
>
>
>
>
>
>
> --- In "cdongyan_tos" <> wrote:
> >
> > Hi all,
> >
> > I can't interrupt the RedBoot on my TS7200 board, both in
> > hyperterminal and minicom. Examining the start-up log, there's sth
> > like "Executing boot script in 0.100 seconds - enter ^C to abort". I
> > just received the board yesterday and haven't changed any setting. I
> > saw some previous threads discussing this problem but didn't see it
> > solved. Is there a solution to it? Thanks very much,
> >
> > - Don
> >
>
> You could try to increase the wait time: check my earlier posts about
> fconfig from linux to do it on a running system.
> You could even try to access it from network. Use
> http://www.nslu2-linux.org/wiki/HowTo/TelnetIntoRedBoot as a guide.
>
>
------------------------------------