> ...that you've used in a TS-7400? I've used the same in i386 and
> x86_64 systems and of course it works OK. Problem is on TS-7400.
> tv_usec has the same value in start and tm.
>
> I wanted to ask before diving into it.
The Cirrus kernel that our kernel is based on has a "bug" where the
microsecond time only has a resolution equal to the clock tick (e.g. it
increments 10,000us at a time). However if you are seeing longer intervals
much longer then 10ms without no us advancement then I agree with the
previous poster who suggested a bug in user code.