> Actually that's much simpler than my pppd idea... sorry about that.
> Michael is right, just run:
> cat /dev/ttyTS1
> at one end and
> echo "whatever" > /dev/ttyTS1
> and watch "whatever" appear on the "cat" end.
> I assume both ZigBees will start with compatible configurations.
> This is the way I test all my serial connections.
Running 'cat' and 'echo' are about as simple as you can get, but you'll want
to make sure all your termios are set up correctly first, as one wrong
termios parameter can cause communications to fail in strange ways. It
sometimes seems termios defaults are pretty much "random", or at least they
can vary from machine to machine and distro to distro.
______ Best Regards,
|__ __/ Michael Schmidt
|| Software Engineer
||echnologic Systems (EmbeddedARM.com)
|| (480) 16610 East Laser Drive #10
|/ 837-5200 Fountain Hills, AZ 85268
http://oz.embeddedarm.com/~michael
------------------------------------
Yahoo! Groups Links