Re: Digest Number 6626

Subject: Re: Digest Number 6626
From: "Scott Fraser" scottbfraser
Date: Fri Jul 15, 2016 5:32 am ((PDT))
> On Jul 15, 2016, at 1:14 AM,  wrote:
>
> What I don't know is what do the dotted lines mean? On my cable (2 separa=
te cables into a 5 pin plug) the ground tag of the plug is not connected to=
 anything, and I suspect that could be why I=92m getting the bad handling n=
oise? >>

The dashed lines would appear to indicate that the circuit is wired unbalan=
ced, by tying the =91cold=92 pins to ground. This would only make sense if =
the mic was to be plugged into unbalanced (2 pole) mic inputs. But the phot=
o shows the connector apparently wired correctly, although we don=92t see w=
hat=92s on the other end. The ground tab would not have any effect on handl=
ing noise, & need not be connected.






<Prev in Thread] Current Thread [Next in Thread>
Admin

The University of NSW School of Computer and Engineering takes no responsibility for the contents of this archive. It is purely a compilation of material sent by many people to the naturerecordists mailing list. It has not been checked for accuracy nor its content verified in any way. If you wish to get material removed from the archive or have other queries about the archive e-mail Andrew Taylor at this address: andrewt@cse.unsw.EDU.AU