Re: Rane link - a warning

Subject: Re: Rane link - a warning
From: "Scott Fraser" scottbfraser
Date: Fri May 10, 2013 6:43 am ((PDT))
< I=B4ve never looked at that connection on the Rane Note before, but upon =
closer look it seems very wrong, yes. I=B4ve never lifted a ground like tha=
t.  >

I don't have the Rane paper in front of me, but there is a scheme for runni=
ng line level unbalanced connections through balanced 2 conductor cable. On=
 the source end the hot signal connects to one of the conductors & the grou=
nd connects to the other conductor, with the shield unconnected. On the des=
tination end the hot conductor goes to hot while the cold conductor is tied=
 to the shield & goes to ground. Back when semi-pro equipment was running l=
ine level on unbalanced RCA connectors I wired an entire studio this way wi=
th Mogami 2 conductor cable. It worked well & was very quiet, but this is o=
nly for line level signals. Microphones need shield connected at both ends =
& phantom power only works into a balanced input.

SF








<Prev in Thread] Current Thread [Next in Thread>
Admin

The University of NSW School of Computer and Engineering takes no responsibility for the contents of this archive. It is purely a compilation of material sent by many people to the naturerecordists mailing list. It has not been checked for accuracy nor its content verified in any way. If you wish to get material removed from the archive or have other queries about the archive e-mail Andrew Taylor at this address: andrewt@cse.unsw.EDU.AU