--- In "Charles" <> wrote:
>
>
> Hi --
>
> --- In "j.chitte" <j.chitte@> wrote:
> >
> > >
> > > what's going on here?
> > >
> >
> > Hi , having similar problems on 7250 with busybox 1.17
> >
> > here reboot is also a nop. I have to power cycle manually.
> >
> > I have another image with recent bb (probably 1.16) that works correctly.
> > Have not had time to dig into it.
> >
> > :?
> >
>
> Look into the config of busybox. In the ./init directory, the reboot, halt
> and poweroff routines all have code like this (from bb 1.00-rc2):
>
> #ifndef CONFIG_INIT
> #ifndef RB_HALT_SYSTEM
> #define RB_HALT_SYSTEM 0xcdef0123
> #endif
> return(bb_shutdown_system(RB_HALT_SYSTEM));
> #else
> return kill_init(SIGUSR1);
> #endif
>
> So looks like if bb is configured as an init replacement, these calls work on
> init, otherwise they work as expected.
>
> May explain why your two binaries work differently, but doesn't explain why
> your TS-7200 works differently than the TS-7500 Kris mentions in another post.
>
> regards, ........ Charlie
>
hi,
I rebooted the image that worked and found I had used sysvinit not BB there so
that explains it .
I'll have to look into what is wrong with the bb installation and where
/sbin/init comes from.
Or maybe just add sysvinit and save myself a day's work ;)
Thanks for the pointer.
------------------------------------
Yahoo! Groups Links
<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/ts-7000/
<*> Your email settings:
Individual Email | Traditional
<*> To change settings online go to:
http://groups.yahoo.com/group/ts-7000/join
(Yahoo! ID required)
<*> To change settings via email:
<*> To unsubscribe from this group, send an email to:
<*> Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/
|