--- In Christian Gagneraud <> wrote:
>
> guilhermerlara wrote:
> > Ihave the TS-7260 e the PC-104 peripheral GSM1.
> > All the AT commands work fine but when i put the command AT*E2IPA=1,1 my
> > board resets!
> > The command work because i see the configuration and the modem is connect e
> > i have an IP (AT*E2IPI).
> > But the board doesn´t stops to reset. Time from time the board
> > automatically resets!!
> > It appear that the exchange of information causes the reset. When i ping
> > the IP given by the modem the board resets.
>
> Change your power supply, the modem pump huge pike of current. It is
> likely your power supply can't handle them, causing the voltage to
> drop down, which in turn cause the board to reset.
>
> If you can't change your power supply, try adding a big capacitor in
> parallel, 4700 uF should do the job, perhaps smaller as well...
>
>
> Regards,
> Chris
>
> >
> > Anyone knows what cause that?
> >
> > Thanks
> >
> >
> >
> > ------------------------------------
> >
> > Yahoo! Groups Links
> >
> >
> >
>
Thanks!!!
The capacitor 4700 uF have done the job!
------------------------------------