Hi Todd,
I spent quite some time trying to get the Bat3 working on a TS-7300 a
while back. It turned out that the local loop back network port
wasn't configured during the quickboot.
I would recommend giving Michael at Technologic Systems a call - he
was very helpful in getting my Bat3 application going.
Regards,
PJE
--- In "todd" <> wrote:
>
> I'm having a problem with the bat3 charging daemon and the TS-BAT3
> board connected to a TS-7260. The daemon keeps quiting because it
> cannot change the AVR state. I have multiple boards and see it on
> all of them, as well as when I run on the default OS image or my own
> that I'm working on. I've also tried the latest bat3 binary that
> is available on the website in addition to compiling from source.
>
> I've sprinkled some printf's in the source (and commented out the
> processDaemonize() call which was closing the stdin/out/err
> file descriptors). I'm running bat3 as:
>
>
> # bat3 --charge 400
>
> I can see it read the initial state, then try to change it in
> the BAT3BatteryCharge() routine. The resulting state never matches
> the requested one, the retries run out and we exit(3).
>
> Sometimes it runs for awhile, sometimes it exits immediately.
>
> I've got the following modules loaded:
>
> # lsmod
> Module Size Used by Tainted: PF
> tsuart-bat3 1212 0 (unused)
> tsuart7260 1668 0 (unused)
> tsuart0 8912 0 [tsuart-bat3 tsuart7260]
> af_packet 9480 0 (unused)
> sdcard0 13408 1
>
> Has anyone experienced this?
>
> Todd
>
Yahoo! Groups Links
<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/ts-7000/
<*> Your email settings:
Individual Email | Traditional
<*> To change settings online go to:
http://groups.yahoo.com/group/ts-7000/join
(Yahoo! ID required)
<*> To change settings via email:
<*> To unsubscribe from this group, send an email to:
<*> Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/
|