Hello,
> I noticed that on the TS7260 the first 3 ADC are used by the system to
> monitor the votages. i am powering the TS7260 a lipo battery so i
> need to monitor the input voltage.
>
> Can user code still read these ADC?
Yes user code can read from those ADCs.
> if so.....
> I would assume we would not have to init them since the system should
> have already done that. Is that correct?
No, you would still need to initialize them.
> also i did not find in the docs which voltage channel 0 monitors?
> channel 1? channel2?
>From the schematic I see the following.
channel 0: Power In(voltage dividor)
channel 1: PC/104 5V(voltage dividor)
channel 2: DIO2 header
channel 3: 1.8V
channel 4: DIO2 header
//Eddie