On Thu, 2007-09-13 at 23:49 +0200, Roman Haefeli wrote:
> On Thu, 2007-09-13 at 17:31 -0400, John Kua wrote:
> > Roman,
> >
> > I recently went through this problem. It seems that using setpwc to disable
> > AGC is pointless, because the next time the camera is accessed, as far as I
> > can tell, it defaults back to AGC on. This, however, is not a pwc problem,
> > nor is it really a setpwc problem. Because the AGC setting resets every time
> > you open the camera for access, you have to disable AGC, set your desired
> > gain AND capture the images you want in one session.
> >
> > In other words, the program you use to capture your images has to set the
> > gain itself.
>
> oh.. thank you a lot for that information. this made a lot things
> clearer for me.
since i don't know much about c coding, i'll just ask:
wouldn't it be possible to change the driver in a manner, that it keeps
the value for agc, that was set by a certain programm beforehand, so
that another programs could use the camera with the same agc setting?
it is very unlikely that all programms i use (mplayer, ffmpeg,
pd/gem/gridflow) will ever support this pwc specific settings, which in
return means, that these settings just cannot be used.
just to know, if that would be feasible, would help me a lot. then i
probably could ask some c coder to do it for me.
roman