To: | Philips Webcam Linux Driver <> |
---|---|
Subject: | [pwc] minor bug in pwc_video_open() |
From: | Michael C Wescott <> |
Date: | Sun, 26 Feb 2006 16:57:37 -0500 |
In pwc_video_open() the camera is sent a poweron command only if the global power_save is set. It is possible to have a camera in the powered off state but also have power_save be zero, for example if the module has been reinstalled with power_save=0 after powering off the camera. In any case, a belt-and-braces approach would be to always send the poweron command. Diff attached. -- Michael C Wescott <>
if.diff _______________________________________________ pwc mailing list http://lists.saillard.org/mailman/listinfo/pwc |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [pwc] spec available, Michael C Wescott |
---|---|
Previous by Thread: | [pwc] spec available, Michael C Wescott |
Indexes: | [Date] [Thread] [Top] [All Lists] |
Disclaimer: Neither Andrew Taylor nor the University of NSW School of Computer and Engineering take any responsibility for the contents of this archive. It is purely a compilation of material sent by many people to the birding-aus mailing list. It has not been checked for accuracy nor its content verified in any way. If you wish to get material removed from the archive or have other queries about the archive e-mail Andrew Taylor at this address: andrewt@cse.unsw.EDU.AU