ME66/K6 with signal bias

Subject: ME66/K6 with signal bias
From: "Peter Shute" pshute2
Date: Sat Oct 26, 2013 3:18 pm ((PDT))
I recently left my ME66 switched on overnight, and when I discovered this i=
n the morning and switched it off and on again, the battery confirmation li=
ght was very dim.

The first recording I made after that seems ok, but a couple after that sho=
w a bias in the signal, showing in the waveform as a funny shaped wave, rep=
eating every 4 seconds or so. Later in the day this decreased to about 1 se=
cond, although the recordings sound ok to me.

I've uploaded a sample to http://snd.sc/1a7KEuG

Is this bias the normal result of a dying battery? When I tested it again j=
ust now before changing the battery, it seemed ok again, perhaps because th=
e battery had recovered a bit. I've left it on to see if I can replicate th=
e problem.

I'm not at all concerned about saving the recording, only about whether the=
 mic is faulty or just needed a fresh battery.

Peter Shute






<Prev in Thread] Current Thread [Next in Thread>
Admin

The University of NSW School of Computer and Engineering takes no responsibility for the contents of this archive. It is purely a compilation of material sent by many people to the naturerecordists mailing list. It has not been checked for accuracy nor its content verified in any way. If you wish to get material removed from the archive or have other queries about the archive e-mail Andrew Taylor at this address: andrewt@cse.unsw.EDU.AU