Re: Tascam DR-680 in the field

Subject: Re: Tascam DR-680 in the field
From: "Luis do Carmo" lecarmo
Date: Sat Apr 27, 2013 2:21 pm ((PDT))
I use NP-1's by Varizoon, but I once found and added to my favorites an int=
eresting thread on this specific subject at another group I follow. http://=
jwsoundgroup.net/index.php?/topic/13669-batteries-for-tascam-dr-680/
Luis



From: Gregory O'Drobinak <>
To: 
Sent: Saturday, April 27, 2013 2:04 PM
Subject: Re: [Nature Recordists] Re: Tascam DR-680 in the field



=C2=A0
Trond & all:

There is another issue with using external batteries with the DR-680 that y=
ou
need to be aware of.

If a lead-acid (AGM or gel cell) battery is left on well past its 'safe'
discharge voltage, the DR-680 does NOT deal with the low input voltage prop=
erly;
it doesn't switch over to the internal batteries as one might expect, until=

things are too late. As the external battery voltage drops, the recorded so=
und
is filled with increasingly large amounts of terrible glitches, then the au=
dio
mutes altogether. Not a pleasant thing to listen to.

There are two solutions to this problem with lead-acid batteries. One is to=

build an in-line circuit for the battery supply that cuts off the supply to=
 the
DR-680 when the voltage drops to about 11.6 volts. Then the internal batter=
ies
will take over properly from the external battery. The other way is to use =
a
battery that has excess capacity to handle extended recording times before =
it
reaches its safe discharge voltage. My rule-of-thumb is to allow for about =
1 AH
of battery capacity for each hour of recording time, based on using 4 mics =
with
phantom power. You should be safe with that amount. As an example, I did a =
14
hour drop at Seney with 4 mics under phantom power using a 22 AH AGM batter=
y
with no issues. So use the biggest battery you can handle. BTW, the power
consumption of the DR-680 does not scale exactly linearly with the amount o=
f
mics used since the recorder uses a fair amount of power even when not usin=
g
phantom power.

My lab measurements put the power consumption of the DR-680 at 0.96 watts (=
800
mA * 12 volts) when using all 6 mic inputs with phantom power. So my
rule-of-thumb for battery capacity is pretty darn close. I always like to h=
ave a
safety factor when dealing with one-of-a-kind recording opportunities.   :>=
}

I don't have any experience with using the BP160 lithium battery pack that =
David
has mentioned, but based on the data sheet one could expect about 15 - 16 h=
ours
of run time for the DR-680 using 6 mics with phantom power. The BP160 has
built-in circuitry that should mitigate any problems with the cutover to th=
e
internal batteries of the DR-680.

All of this boils down to price versus size and weight. One can buy almost =
five
22 AH AGM batteries that each have equivalent capacity to the BP160 battery=

pack, but they are heavy and bulky compared to their lithium counterpart.

As for toxicity, all batteries have some toxic chemicals within them. All
batteries should be disposed of at a proper disposal facility after they ar=
e no
longer usable. BTW, I have never had any health issues using and handling A=
GM
(lead acid) batteries. One can recycle them at many battery shops for free;=
 the
internal contents are then used to make new batteries.

Finally, here are some links for the curious:
http://www.batteryweb.com/manuals/techman.pdf

http://batteryuniversity.com/learn/article/health_concerns

I hope that this helps to elucidate the subject of batteries and the DR-680=
.

Best regards,
Greg O'Drobinak

<Prev in Thread] Current Thread [Next in Thread>
Admin

The University of NSW School of Computer and Engineering takes no responsibility for the contents of this archive. It is purely a compilation of material sent by many people to the naturerecordists mailing list. It has not been checked for accuracy nor its content verified in any way. If you wish to get material removed from the archive or have other queries about the archive e-mail Andrew Taylor at this address: andrewt@cse.unsw.EDU.AU