        here some preliminary info on the performances of the EMU TrackerPre, a pretty cheap though reliable USB acquisition device able to run up to 192k with good performances.

The frequency response at 192k is flat up to 84kHz and rolls down 1 dB at 90kHz and 6 dB at Nyquist (96kHz). The a-a filters are steeper than those of the USBPre2:

INPUT at 0dB                            ALIAS
100kHz                                    -16dB at 92kHz
102kHz                                    -25dB at 90kHz
104kHz                                    -50dB at 88kHz
112kHz                                    at 80kHz the aliasing components are not measurable                                  

More accurate tests and graphs will follow on on our website at http://www.unipv.it/cibra/res_techtest_uk.html

Gianni


--
Presidente
Centro Interdisciplinare di Bioacustica e Ricerche Ambientali
Dipartimento di Biologia Animale
Universita' di Pavia
Via Taramelli 24 - 27100 PAVIA
http://www.unipv.it/cibra
http://mammiferimarini.unipv.it
Phone +39-0382-987874

<Prev in Thread] Current Thread [Next in Thread>
  • EMU TrackerPre, Gianni Pavan <=
Admin

The University of NSW School of Computer and Engineering takes no responsibility for the contents of this archive. It is purely a compilation of material sent by many people to the Bioacoustics-L mailing list. It has not been checked for accuracy nor its content verified in any way. If you wish to get material removed from the archive or have other queries about the archive e-mail Andrew Taylor at this address: andrewt@cse.unsw.EDU.AU